Intuitive Vision System
CV-5000 series
Recommended Replaceable Products: Intuitive Vision System - CV-X series
Contact Us: +63-(0)2-8981-5000 Enquiry form
Digital Image Sensor/Controller CV-5001
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | CV-5001 | |||
Type | Controller | |||
No. of pixels | • 512 (H) × 480 (V), Approx 240,000 pixels • 640 (H) × 480 (V), Approx 310,000 pixels | |||
Camera input | Two colour/monochrome | |||
Main processor for image processing | DSP | |||
No. of registered settings | SD cards 1 and 2 can each hold 1000 programs (depending on the size of the SD | |||
Number of screens that can be registered | Maximum 1000 screens for each program (depending on SD card size), | |||
Internal memory capacity | SD card slot x2 (SDHC compatible) | |||
Window | Measurement area | 128 locations per program | ||
Mask area | 4 locations per area | |||
Colour extraction function (valid only when a colour camera is connected) | Colour binary, colour shade, Gray, RGB average gray (Colours can be specified | |||
Measurement | Area measurement | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc or polygon (up to 12 | ||
Position detection | Pattern search | • Multiple searches possible for both pattern area and search area. The shapes are | ||
V-search | • Up to 256 patterns can be searched simultaneously for both pattern area and | |||
ShapeTrax2 | • Multiple searches possible for both pattern area and search area. The | |||
Edge position | • Angles can be measured. The shapes are rectangle, rotated rectangle, | |||
Trend edge position | • Circle or straight line can be measured from the detection results | |||
Blob (Centre of gravity) | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc or polygon (up | |||
Inspection mode | Edge position | |||
Edge pitch | ||||
Edge count | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to | |||
Edge angle | Shape is rectangle. | |||
Pair edge | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to | |||
Trend edge width | Shapes are rectangle, rotated rectangle, ring and arc | |||
Blob (characteristic quantities) | • Labels, center of gravity, main axis angle, area, feret diameter, perimeter, | |||
Stain detection | • Subtract stain detection by using subtract filter | |||
Trend edge flaw | • The shapes are rectangle, circle, oval, ring, arc, and polygon. | |||
Intensity inspection | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to | |||
Colour (only when a Colour camera is connected) | • RGB and HSB measurement supported | |||
Geometry | • Calculation result can be reflected | |||
OCR | • Character recognition for max. 2 lines of 20 characters per line | |||
Interface | Control input | External trigger input | 2 points | |
Control input | 18 inputs | |||
Control output | Universal output | 27 outputs NPN (including two FLASH outputs linked to external trigger.) | ||
Total comparator output | 1 output, NPN open collector, maximum 50 mA (30 V or less) | |||
Monitor output | SVGA 800x600 (24-bit colour 60 Hz) | |||
Run indicator | Power, Error LED display | |||
RS-232C | Numerical value output, image data (compressible) and control input/output | |||
Ethernet | Numerical value output, image data (compressible) and control input/output enabled. | |||
USB | Numerical value output, image data (compressible) and control input/output | |||
PLC link | Numerical value output and control input/output using the RS-232C port or | |||
CC-Link | By connecting the optional CC-Link unit CA-NCL10E, numerical value input/ | |||
EtherNet/IP™ | Numerical value input/output and control input/output enabled while using an | |||
Illumination control | By connecting the optional illumination expansion unit, LED illumination (12 V, 24 | |||
Continuous capture function | • 1 to 32-time multi-measurement (maximum, minimum and average values) | |||
Execution condition setting function | Can set whether to execute the results (OK/NG) for other measurement and | |||
Image | Processing area setting function | 240,000 pixels (512 (H) x | ||
Scan mode | Progressive/interlace selectable | |||
Capturing start/end line setting function | Desired capture start/end line can be set within the image capture range. | |||
Correction | Position adjustment | Batch, individual (maximum 128 settings), X, Y, ±180° rotation. | ||
Camera gain adjustment | Sensitivity adjustment, offset, and span adjustment | |||
White balance adjustment (valid only when a colour camera is connected) | Manual setting using white paper | |||
Image inversion function | Can generate mirror images | |||
Scaling function | X and Y calibration setting for each camera. Conversion from measurement | |||
Filter function | Count | The same type of filter can be used up to 9 times. 13 steps. | ||
Type | Expand, shrink, average, median, edge sharpening, edge extract X, edge extract | |||
Display language | Japanese/English/German/Italian/French/Traditional Chinese/Simplified Chinese | |||
Calculation | Numerical | No. of settings | 128 calculations/1 program | |
Arithmetic operation | +, -, x, ÷ | |||
Arithmetic function | Square, exponential, counting fractions as one, round-off fractions, maximum, minimum, average, average within range, | |||
Comparative operator | <, ==, Not | |||
Geometric calculation | Distance between 2 points, angle of line segment, circle radius, circle center, | |||
Coordinate conversion function. | Coordinate system conversion, rotating matrix | |||
Type conversion function | Coordinate constant conversion, constant coordinate conversion, | |||
Logical operator | AND, OR, NOT, XOR | |||
Sort function | Maximum value index output, minimum value index output | |||
System function | Number of measurement times, measurement time, year, month, day, time, minute, second | |||
Time axis operation function | Previous measurement result acquisition operator | |||
Command memory | 1000 command memories that can be rewritten from external devices | |||
Support | Statistics analysis | No. of data | Max. 20000 data (can be saved into an SD card in a batch) | |
Statistical items | Maximum, minimum, average value, deviation (3σ), total status OK/NG times | |||
Screen save (valid when monochrome | The following number of | |||
Programming aid | Image Zoom | Between 4% and 1600% during setting or operation (6% and 2500% during full | ||
Edge derivative wave display | Edge waveform can be graphically displayed during setting or operation, and | |||
Profile display | Trend edge position and gap can be graphically displayed during setting or | |||
Stability display | Stain detection (stain level) is displayed during setting or operation. | |||
Cutout projection waveform display | OCR automatic cutout waveform graphics can be displayed during setting or | |||
Shift all windows | Selected windows from an identical camera or an identical registered image can | |||
Flaw level waveform | The flaw level waveform of the trend edge tool can be displayed as a graphic in | |||
Display template | No. of display templates | 10 templates/1 program (within which 4 templates are specified values), | ||
No. of screens that can be displayed simultaneously | Max. 5 screens can be displayed at the same time | |||
Hold image | Up to the past three images (NG images) can be displayed as hold images. | |||
Screen customisation | No. of customised screens | 10 screens/1 program | ||
Custom item | Character string: Measurement value (decimal point can be specified), result, | |||
Measurement result interlink | • Display colour can be changed according to the result for figures and custom | |||
Operation rewrite function | • Upper/lower tolerance or command memory can be rewritten during operation. | |||
Emulation function | Built-in emulation function that can create new program data and save data on | |||
Program file update function | The program data used on the CV-3001 Series or CV-5001FE can be converted | |||
Custom menu function | Shortcut menu to a desired program screen can be created (20 menus/program). | |||
Memory card save function (SD2 slot only) | • Measurement value, judgment result, NG count, measurement image | |||
Others | Screen capture function, password function, re-test function, file management | |||
Rating | Power voltage | 24 VDC ±10 % | ||
Current consumption | 2.2 A (2 cameras at maximum load) | |||
Environmental resistance | Ambient temperature | 0 to +50 °C | ||
Relative humidity | 85% RH or less (no condensation) | |||
Weight | Approx. 1,250 g | |||
*1 Some models also are compatible with the RS-232C, Ethernet ports in the system. |