Ultra-small Digital Laser Sensor

LV-S series

Catalogues View Catalogue

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Recommended Replaceable Products: Multi-Purpose Digital Laser Sensor - LV-N series

Amplifier Unit, Main Unit, PNP LV-11SBP

LV-11SBP - Amplifier Unit, Main Unit, PNP

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

  • CE Marking
  • UL Recognition(c/us)

Specifications

Model

LV-11SBP*1

Type

Main unit

Output

PNP

Control output

PNP open-collector x 2 ch 30 VDC max. 100 mA max. per output

Response time

ExceptLV-S31

ULTRA

4 ms

SUPER

2 ms

TURBO

500 µs

FINE

250 µs

HSP

80 µs

LV-S31standard mode

500 µs

LV-S31standard mode

SPED2

2 ms

SPED3

8 ms

SPED4

32 ms

LV-S31High-speed mode

250 µs

Control input

Light emission stop input, external calibration, set value bank selection input, or shift input

Number of interference prevention units

ULTRA

4*2

SUPER

TURBO

2*2

FINE

HSP

0*2

Unit expansion

Up to 16 expansion units can be installed (17 units including the main unit)*3

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*4

Power consumption

Normal

1.7 W max. (70 mA max. for 24 V)

Eco-Half Eco-All

1.55 W max. (65 mA max. for 24 V)

Environmental resistance

Ambient temperature

-10 to +55 °C (No freezing)*5

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

Material

Main unit

Main body, cover: Polycarbonate

Weight

Approx. 80 g (including 2 m cable)

*1 LV-S62 and LV-S63 can ONLY be used with amplifiers ending with B or BP.
*2 Numbers for the LV-S31 are four in standard mode and two in high-speed mode.
*3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows:
1 to 2 units connected: -10 to +55ºC (14 to 131ºF)
3 to 10 units connected: -10 to +50ºC (14 to 122ºF)
11 to 16 units connected: -10 to +45ºC (14 to 113ºF)
*4 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % max.
*5 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C

Data Sheet (PDF) Other Models