Multi-Purpose Digital Laser Sensor

LV-N series

Catalogues View Catalogue

Amplifier, M8 Connector, Main unit, NPN LV-N11CN

LV-N11CN - Amplifier, M8 Connector, Main unit, NPN

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

LV-N11CN

Type

1 output

Output

NPN

Cable/connector

M8 connector

Main/Expansion unit

Main unit

I/O

Control outputs

1 output

External input

1 input

Monitor output

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
Timer duration selectable: 1 ms to 9,999 ms,
Maximum error against the setting value: ±10% max.

Control outputs

NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less

Response time

80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

Monitor output

-

External input

Input time 2 ms (ON)/20 ms (OFF) or more*2

Number of interference
prevention units

Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

Case size

H 32.6 mm × W 9.8 mm × L 78.7 mm

Unit expansion

Up to 17 units can be connected in total (two-output type is treated as two units)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS

Power
consumption

Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*4
Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*4
Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)
*5

Environmental resistance

Ambient temperature

-20 to +55 °C (No freezing)*6

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Cable

PVC

Case

Main unit and cover material: Polycarbonate

Weight

Approx. 20 g

*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
*3 These numbers double when "DOUBLE" is selected.
*4 Increases 30 mW (1 mA) for High Speed mode.
*5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
*6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
One or two more units connected: -20 °C to +55 °C ; 3 to 10 more units connected: -20 °C to +50 °C; 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units.

Data Sheet (PDF) Other Models