Non-contact type Standard type NPN Standard cable 5 m GS-11N5

GS-11N5 - Non-contact type Standard type NPN Standard cable 5 m

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • UL Listing(c/us)
  • CSA

Specifications

Model

GS-11N5

Type

Standard type

Output type

NPN

Operating distance

Front

Sao(OFF→ON)

10 mm

Sar(ON→OFF)

18 mm

Side

Sao(OFF→ON)

6 mm

Sar(ON→OFF)

14 mm

Response time

Detection

Detect →Not detect

20 ms + 2 ms × (number of units cascaded -1) *1

Not detect →Detect

30 ms + 25 ms × (number of units cascaded -1) *1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

Max. 30 units

Using Y-shaped connector

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 100 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m)

OFF state voltage

Max 2.0 V (with a cable length of 5 m)

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m)

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Current consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C (No freezing)

Storage temperature

-25°C to +70°C (No freezing) *2

Operating relative humidity

5% to 95% RH

Storage relative humidity

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm, 5 minutes in each of the X, Y and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 270 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When stored for a long period of time, please store it at a temperature of 55°C or lower.

Data Sheet (PDF) Other Models