Ultra High-Speed/High-Accuracy Laser Displacement Sensor

LK-G5000 series

Catalogues View Catalogue

Specs Ultra High-Speed/High-Accuracy Laser Displacement Sensor LK-G5000 series

Sensor heads: Diffuse reflection mode

Model

LK-H020

LK-H025

LK-H050

LK-H055

LK-H022

LK-H027

LK-H052

LK-H057

Image

Mounting mode

Diffuse reflective

Reference distance

20mm

50 mm

20mm

50 mm

Measuring range

±3 mm*1

±10 mm*1

±3 mm*1

±10 mm*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

4.8mW

0.95mW

Spot diameter (at standard distance)

ø25 µm

25 µm x 1,400 µm

ø50 µm

50 µm x 2,000 µm

ø25 µm

25 µm x 1,400 µm

ø50 µm

50 µm x 2,000 µm

Linearity

±0.02% of F.S. (F.S.= 6 mm)*2

±0.02%of F.S.
(F.S.= 6 mm)*2

±0.02% of F.S. (F.S.= 20 mm)*2

±0.02% of F.S.
(F.S.= 20 mm)*2

±0.02% of F.S. (F.S.= 6 mm)*2

±0.02%of F.S.
(F.S.= 6 mm)*2

±0.02% of F.S. (F.S.= 20 mm)*2

±0.02% of F.S.
(F.S.= 20 mm)*2

Repeatability

0.02 µm (0.01 µm)*3

0.025 µm*3

0.02 µm (0.01 µm)*3

0.025 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 6 mm)

0.01% of F.S./°C
(F.S.= 6 mm)

0.01% of F.S./°C (F.S.= 20 mm)

0.01% of F.S./°C
(F.S.= 20 mm)

0.01% of F.S./°C (F.S.= 6 mm)

0.01% of F.S./°C
(F.S.= 6 mm)

0.01% of F.S./°C (F.S.= 20 mm)

0.01% of F.S./°C
(F.S.= 20 mm)

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C*4

0 to +50 °C

0 to +50 °C*4

0 to +50 °C

0 to +50 °C*4

0 to +50 °C

0 to +50 °C*4

0 to +50 °C

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Aluminium die-cast

Weight

Approx. 230 g

Approx. 260 g

Approx. 230 g

Approx. 260 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C or more, mount this on a metal plate before use.

Back to top

Sensor heads: Diffuse reflection/Specular reflection mode

Model

LK-H080

LK-H085

LK-H150

LK-H155

LK-H082

LK-H087

LK-H152

LK-H157

Image

Mounting mode

Diffuse reflective

Diffuse reflective / Specular reflective*5

Reference distance

80 mm

150 mm

Diffuse reflective: 80 mm
Specular reflective: 76.7 mm

Diffuse reflective: 150 mm
Specular reflective: 147.5 mm

Measuring range

±18 mm*1

±40 mm*1

Diffuse reflective: ±18 mm
Specular reflective: -17.6 mm to +14.5 mm*1

Diffuse reflective: ±40 mm
Specular reflective: -39.5 mm to +24.4 mm*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

4.8mW

0.95mW

Spot diameter (at standard distance)

ø70 µm

70 µm x 2,500 µm

ø120 µm

120 µm x 4,200 µm

ø70 µm

70 µm x 2,500 µm

ø120 µm

120 µm x 4,200 µm

Linearity

±0.02% of F.S. (F.S.= 36 mm)*2

±0.02% of F.S.
(F.S.= 36 mm)*2

±0.02% of F.S. (F.S.= 80 mm)*2

±0.02% of F.S.
(F.S.= 80 mm)*2

±0.02% of F.S. (F.S.= 36 mm)*2

±0.02% of F.S. (F.S.= 80 mm)*2

Repeatability

0.1 µm*3

0.25 µm*3

0.1 µm*3

0.25 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 36 mm)

0.01% of F.S./°C
(F.S.= 36 mm)

0.01% of F.S./°C (F.S.= 80 mm)

0.01% of F.S./°C
(F.S.= 80 mm)

0.01% of F.S./°C (F.S.= 36 mm)

0.01% of F.S./°C (F.S.= 80 mm)

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Incandescent lamp or fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Aluminium die-cast

Weight

Approx. 280 g

Approx. 300 g

Approx. 280 g

Approx. 300 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C or more, mount this on a metal plate before use.
*5 Use one of the following dark filters when measuring a transparent or mirror surface object: LK-H082/LK-H087: LK-F3, LK-H152/LK-H157: LK-F2

Back to top

Sensor heads: Specular reflection mode

Model

LK-H008

LK-H008W

LK-H022K

LK-H027K

LK-H052K

LK-H057K

Image

Mounting mode

Specular reflective

Reference distance

8mm

16.1mm

46.3mm

Measuring range

±0,5 mm*1

±0.5 mm*1

±2.8 mm*1

±5.2 mm*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 1
FDA(CDRH)21CFR Part 1040.10: Class II

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.3mW

0.95mW

Spot diameter (at standard distance)

ø20 µm

20 µm x 550 µm

ø25 µm

25 µm x 1,400 µm

ø50 µm

50 µm x 2,000 µm

Linearity

±0.05% of F.S. (F.S.= 1 mm)*2

±0.02% of F.S. (F.S.= 6 mm)*2

±0.02% of F.S. (F.S.= 20 mm)*2

Repeatability

0.005 µm (0.001 µm)*3

0.02 µm (0.01 µm)*3

0.025 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.02% of F.S./°C (F.S.=1 mm)

0.01% of F.S./°C (F.S.= 6 mm)

0.01% of F.S. (F.S.= 20 mm)

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C*4

0 to +50 °C

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Aluminium die-cast

Weight

Approx. 240 g

Approx. 230 g

Approx. 260 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C or more, mount this on a metal plate before use.

Back to top

Main unit

Model

LK-G5001V*1*2

LK-G5001PV*8*2

Image

Separate type

LK-G5001/LK-HD500

LK-G5001P/LK-HD500

Type

Main controller

Sensor head compatibility

Compatible

No. of connectable sensor heads

2

Display

Minimum display unit

LK-HD500: 0.001 µm

Display range

LK-HD500: ±999.999 µm to ±9,999.99 mm (7 settings selectable)

Display cycle

LK-HD500: Approx. 10 times/sec.

Display interface

Display port

Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected

LED indicator

LASER ON

Terminal block

Analogue output voltage

±10 V output, Output impedance: 100 Ω

Analogue current output

4 to 20 mA, Maximum load resistance: 350 Ω

No. of analogue outputs

2

TIMING 1 input

Non-voltage input*3

Voltage input*3

RESET 1 input

Auto-zero 1 input

Laser control input

Non-voltage input*4

Voltage input*4

Laser remote input

Non-voltage input

Alarm output

NPN open-collector output

PNP open-collector output

General comparator output

Expansion connector

TIMING input

Non-voltage input

Voltage input

RESET input

Auto-zero input

Program switching input

Binary selection input

Alarm output

NPN open-collector output

PNP open-collector output

Comparator output

Binary output

RS-232C interface

Baud rate: 9,600 to 115,200 bps
Data length: 8 bits, Stop bit length: 1 bit, Parity: None/even/odd

USB interface

USB 2.0 Hi-Speed compliant*5

Ethernet interface

100Base-TX/10Base-T*6

EtherNet/IP™interface

Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3
Number of connections: 32
Complies with conformance test version CT14*7

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Expansion unit connector

Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected

Power supply

Power supply voltage

24 VDC ±10 %

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C.
When two or more head expansion units are connected: 0 to +40 °C.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 600 g

*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
*2 Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual.
*3 This input is applied to all of the synchronized OUT.
*4 When the laser class 3B sensor head is connected, a key-operated switch must be used for the input to this terminal. The laser is emitted only when the key-operated switch is set to the ON position. (Select a key which can be removed only when it is set to the OFF position.)
When the laser class 1/2/3R sensor head is connected, the laser turns on when this terminal is opened and turns off when it is short-circuited.
*5 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*6 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*7 The EtherNet/IP™ interface cannot be used when a CC-Link unit or a DeviceNet® unit is installed.
EtherNet/IP™ is supported by the latest controllers. For details on which controllers support EtherNet/IP™ , contact your nearest KEYENCE office.
*8 PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA

Back to top

Head expansion unit

Model

LK-HA100

Image

Separate type

LK-HA100

Type

Head expansion unit

Sensor head compatibility

Compatible

No. of connectable sensor heads

1

Display interface

LED indicator

POWER ON, STABILITY, BRIGHT, DARK

Terminal block

Analogue output voltage

±10 V output, Output impedance: 100 Ω

Analogue current output

4 to 20 mA, Maximum load resistance: 350 Ω

No. of analogue outputs

1

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Power supply

Power supply voltage

24 VDC ±10 % (Supplied from the controller)

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C.
When two or more head expansion units are connected: 0 to +40 °C.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 300 g

Back to top

LK-G5000 Series Touch Panel Display

Model

LK-HD1001

Image

Type

LK-G5000 Series Touch Panel Display

Display panel

Display colour

TFT colour LCD

32,768 colours

Pixels

W 640 × H 480 pixels

Display area

W 170.9 × H 128.2 mm

Displaypanel

Service life (normal temperature andhumidity)

Approx 50,000 hours

Backlight

Method

White LED

Duration

Approx 50,000 hours

Touch switch

Number of switches

40 × 30 per 1 image

Touchswitch

Method

Matrix resistance membrane mode

Operating force

0.98N or less

Life-span

More than one million times

Communication feature

Available only with the LK-G5000 Series

Structure

Panel built-in type, IP65f equivalent dust-proof, waterjet-proof on only front panel

Power supply

Power supply voltage

24 VDC ±10%

Maximum current consumption

1 A or less

Environmental resistance

Ambient temperature

0 to +50 °C

Storage temperature

-10 to +60 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)*1

Storage relative humidity

35 to 85 % RH (No condensation)*2

Operating environment

No dust or corrosive gas

Vibration resistance

10 to 57 Hz, Double amplitude 0.3 mm, 57 to 500 Hz, 2 G for 3 hours in each of the X, Y, and Z directions

Weight

Approx. 1,150 g

*1 When the ambient temperature is higher than +40 °C, limit the absolute humidity to 85 % RH at +40 °C.
*2 When the ambient temperature is higher than 40 °C, limit the absolute humidity to 85 % RH at 40 °C.

Back to top

Sensor head-to-controller cable

Model

CB-A07

CB-A2

CB-A5

CB-A10

CB-A20

CB-A30

Image

Length

0.7 m

2 m

5 m

10 m

20 m

30 m

Weight

Approx. 100 g

Approx. 200 g

Approx. 400 g

Approx. 550 g

Approx. 1,400 g

Approx. 2,000 g

Back to top

Sensor head-to-controller extension cable

Model

CB-A5E

CB-A10E

Image

Length

5 m

10 m

Weight

Approx. 400 g

Approx. 750 g

Back to top

CC-Link unit

Model

LK-CC100

Image

Type

CC-Link communication unit dedicated to LK-G5000 Series

Network connection

Supported CCLink version

Ver. 1.10 (Extended cyclic setting: Single) Ver. 2.00 (Extended cyclic setting: Double or more)*1*2

Master unit

CLPA-certified master unit (CC-Link Ver. 2.00/Ver. 1.10)

No. of occupied stations

1 to 4

Communication speed

156kbps、625kbps、2.5Mbps、5Mbps、10Mbps

Connection cable

Dedicated CC-Link cable supporting Ver. 1.10 (Shielded 3-core twisted-pair cable: OP-79426, OP-79427)

Maximum total cable extension length

156kbps…1200m、 625kbps…900m、 2.5Mbps…400m、 5Mbps…160m、 10Mbps…100m

Station type

Remote device station

Power supply

Power supply voltage

24 VDC ±10 % (supplied from controller)

Maximum current consumption

200mA or less

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C.
When two or more head expansion units are connected: 0 to +40 °C.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 300 g

*1 The LK-G5000 Series supports the "extended cyclic transmission" and "station-to-station cable length relaxation" of CC-Link Ver. 2.00.
*2 CC-Link is a registered trademark of Mitsubishi Electric Corporation.

Back to top

DeviceNet unit

Model

LK-DN100

Image

Type

DeviceNet® communication unit dedicated to LK-G5000 Series

Network connection

Master unit

ODVA-certified master unit

Maximum trunk line cable length

Thick cable: 500 m (at transmission speed of 125 kbps)/250 m (at 250 kbps)/
125 m (at 500 kbps) Thin cable: 100 m (at all transmission speed settings)

Communication protocol

DeviceNet®*1 compliant

Transmission speed

500 kbps, 250 kbps, 125 kbps

Device type

Generic

Transmission medium

Dedicated 5 cables (2 signal cables, 2 power supply cables, 1 shielding cable)

Communication type

I/O communication (Poll) Explicit message communication

Power supply

11 to 25 VDC

Current consumption

10 mA max. (when network power supply 24 V is applied)

Power supply

Power supply voltage

24 VDC ±10% (supplied from controller)

Maximum current consumption

200mA or less

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C.
When two or more head expansion units are connected: 0 to +40 °C.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 300 g

*1 DeviceNet® is a registered trademark of ODVA (Open DeviceNet® Vendor Association).